According to the client’s description from the cement plant they adopted the vertical mill for the raw meal preparation, then conveying through an air slide chute system (630X79500mm), the angle of inclination is 8 degrees, with 2 blows (18.5KW). Recently, many blocking problems happened at the upper side of the air slide system (around 800mm to cyclone), always happens when the mill starts to work, but when the mill operating for some time, the blocking problem disappears.